Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Diagnosis (Berl) ; 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38696342

RESUMO

OBJECTIVES: It has been recognized that shortened activated partial thromboplastin time (aPTT) may be caused by various preanalytical conditions. As coagulation Factor VIII is included in the in vitro intrinsic coagulation cascade measured by aPTT, we hypothesized that the shortened aPTT could be a result of elevated FVIII activity. We aimed to inspect the connection of elevated FVIII with shortened aPTT, and the possible effect inflammation has on routine laboratory parameters. METHODS: 40 patients from various hospital departments with aPTT measurement below the lower limit of the reference interval (<23.0 s) were included in the study. To compare the obtained results with aPTT measurements in the non-inflammatory state, samples from 25 volunteers (laboratory personnel) were collected. White blood cell count, C-reactive protein, aPTT, and FVIII values were measured in the control group. RESULTS: Only two samples among 40 patients with shortened aPTT (5 %) were clotted. Out of the remaining 38, 26 had FVIII activity above 150 % (upper limit of a reference interval), median value of 194 % (IQR: 143-243 %). Seven samples in the control group had shortened aPTT results (36 %). However, all coagulation samples were clot and hemolysis-free. Multiple regression identified only FVIII activity as an independent variable in predicting aPTT values (p=0.001). CONCLUSIONS: Our results support the thesis that shortened aPTT is rarely a consequence of preanalytical problems. Elevated FVIII activity causes shortened aPTT, not only in the inflammatory state but also in individuals with concentration of inflammatory markers within reference intervals.

2.
Blood Coagul Fibrinolysis ; 35(3): 129-132, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38358906

RESUMO

Although clear and detailed recommendation regarding the lupus anticoagulant mixing test exist, various sources of NPP are used. We decided to inspect the possible differences in mixing studies depending on the mixing media. Four types of mixing media were prepared for 45 random remnant plasma samples: standard human plasma, control plasma N, previously analyzed patient with normal coagulation values, and home-made normal pool plasma (NPP). Samples were analyzed by using Siemens Dade Actin FSL Activated PTT Reagent on BCS XP analyzer. The median aPTT values of mixing studies with commercial lyophilized NPP, with commercial IQC, as well as with a patient did not differ (26.6, 26.3, and 26.8 s, respectively). Median value of a mixing study with home-made NPP was significantly higher from the rest of the group (27.9 s) ( P  < 0.05). According to the obtained results, we decided to employ the commercial lyophilized NPP for future lupus anticoagulant mixing studies.


Assuntos
Síndrome Antifosfolipídica , Inibidor de Coagulação do Lúpus , Humanos , Testes de Coagulação Sanguínea/métodos , Coagulação Sanguínea , Tempo de Tromboplastina Parcial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA